Boiler & Radiant Heating in Corte Madera & Larkspur

High-efficiency boiler replacement $8,500–$15,000 · boiler + indirect water heater $19,000–$29,000 · free written estimate before any work starts.

Hydronic heat in the twin towns runs from bayside slabs on filled marsh to redwood-shaded houses up Madrone Canyon. Local Plumbing services, repairs and replaces boilers, radiant floors and the pumps, tanks and valves around them, and in April 2026 we rebuilt a Larkspur mechanical room around new NTI condensing boilers.

Book online and we’ll call to confirm a time. House cold tonight? Call or text instead.

★★★★★ 5.0 on Google · 340+ reviews C-16 & C-36 Lic #1091739 Open 24/7

Our San Rafael shop is a few minutes up Highway 101 · Corte Madera · Larkspur · Contact us

New NTI wall-hung condensing boilers on a fresh copper and ProPress piping wall with radiant manifolds, expansion tanks and circulators in a Larkspur mechanical room
Hydronic only boilers, radiant floors & indirect tanks
Combustion readings before and after every boiler service
Town, City or County permit pulled for you
Written estimate before any work

No heat in Corte Madera or Larkspur? Call or text (415) 234-0370. We find the fault first and give you a price in writing before we fix it.

Twin towns, three kinds of ground

Corte Madera and Larkspur share a school district, a police force and a Fourth of July parade. Where the house sits, on old bay mud, near the creek or up a wooded canyon, matters more to the boiler than the town line does.

Town since 1916

Old Corte Madera & the hill

Around the old train-station square, most buildings date from the 1920s and 1930s, with some New England-style houses nearby. Christmas Tree Hill climbs toward Mount Tamalpais behind them. Census data puts the town’s median home build year at 1962, so the typical boiler room here is a mid-century house that has been remodeled more than once. That often leaves zones added by different people in different decades, and we map them before recommending anything.

Bayside

Marina Village & Mariner Cove

The Town says these shoreline neighborhoods were built on filled bayland and have settled as much as four feet since construction, as the bay mud underneath compresses. A house that slowly moves can strain rigid piping, and on bayside homes we pay attention to where supply and return lines enter a slab or crawlspace and whether a leak is showing up on the pressure gauge.

City since 1908

Larkspur, Madrone Canyon & Greenbrae

Larkspur’s downtown along Magnolia Avenue has been a National Register historic district since 1982. Madrone Canyon follows Larkspur Creek through a redwood grove. Census data puts the city’s median build year around 1970. Part of Greenbrae lies inside Larkspur and part is unincorporated County land, which decides who issues the boiler permit.

From our job files in the twin towns

Larkspur · April 2026 · two tired boilers out, NTI TRX150 in

This Larkspur house had two older wall-hung boilers in a garage-style mechanical room, feeding radiant floors and hydronic heat. We kept the job a like-for-like swap for the home’s actual heating demand, but we didn’t just hang new boilers on old plumbing. The new NTI condensing boilers (TRX150 Series II) went up on a new copper and ProPress wall. Along with them went a new heating pump, a thermostatic mixing valve, an automatic fill, two thermal expansion tanks, an air separator and a magnetic dirt filter.

The flue now runs out through a side wall. A wall-mounted NTI S20W stainless indirect tank makes the house’s hot water off the boiler. We ran both the hydronic and radiant sides, set the boiler parameters, connected Wi-Fi monitoring with the owner, and hauled the old units away. NTI’s factory warranty covers the boilers, and our labor warranty on this job is three years.

Before: two older teal wall-hung boilers in a Larkspur garage mechanical room, ready for replacement

Corte Madera · October 2025 · a crowded mechanical room, rebuilt

A larger Corte Madera home with many zones of radiant floor and hydronic heat. The scope called for a pair of NTI TRX199 Series 2 condensing boilers, connected to the existing water, gas, heating and flue piping. We replaced every component in the room except the radiant loop circulators, which were still sound.

The domestic hot water side got a new NTI Trinity Stor 116-gallon storage tank, with new piping, strapping, valves and unions. After calibrating the boilers, we ran each heating circuit, set up the controls and Wi-Fi monitoring, and removed the old equipment. The floor supply and return lines are labeled at the boilers, so the next technician can see which loop is which.

NTI TRX199 condensing boiler beside a large NTI indirect storage tank in a dense multi-zone Corte Madera mechanical room

Smaller calls in the same two towns

  • Corte Madera, November 2025: a leaking radiant water line. We drained that section, cut out the leaking pipe, repaired it with approved materials, then restarted the loop from the room thermostat and documented the pipe heating up. Where a repair joint ends up under a floor, we tell you plainly that it’s a sound repair but not ideal practice on a heating loop, and we don’t warranty a joint left underfloor.
  • Corte Madera, December 2025: a commercial building’s rooftop boiler. We replaced the autofill assembly with a new backflow preventer, pressure-reducing valve, bypass and gauges, then refilled the system to about 45 psi with the bypass left closed.
  • Larkspur, January 2026: full system service. Burner and heat exchanger cleaning, a flush with fresh water and inhibitor, an expansion tank recharge and a heat-camera check of every pump. We also added a thermal expansion tank at the water heater.
  • Corte Madera, July 2026: service on several condensing boilers, including Navien units, with combustion analysis before and after.

What a twin-towns boiler tells you before it fails

Most no-heat calls start as something small that went on for weeks. Here is what we look for when you describe it.

The pressure gauge keeps creeping down

Water is leaving the loop somewhere: a pinhole in a radiant line, a weeping relief valve, or a fitting in a slab or crawlspace. An autofill that tops it up quietly can hide the leak for months.

We isolate zones one at a time to find the loop that loses pressure, then locate the leak.

A warm spot or damp patch on the floor

On a radiant house, a heating line leaking under or inside the floor. On bayside lots, settling is one reason to rule this out early.

We confirm it with pressure and temperature, then open up only the section that needs repair.

Boiler fires, stops, fires again

Short cycling: too little flow through the boiler, a clogged dirt filter or strainer, or a boiler oversized for the zone that’s calling.

We check flow, the filters and the setup, which is often a settings fix rather than a parts job.

The indirect tank only gets lukewarm

A domestic hot water priority setting, a failed tank sensor, a mixing valve set too low, or scale on the coil.

We test the sensor, mixing valve and priority logic before anyone talks about a new tank.

Lockout codes after a wet week

Condensing boilers can lock out on a blocked condensate line, a soaked intake, or a vent termination that takes on wind-driven rain.

We flush the condensate trap, swap spent neutralizer media, look over both vent terminations and pull the stored lockout codes.

A pump that hums but rooms stay cool

A circulator that has seized or is near the end of its life, or a zone valve that no longer opens.

We test each pump and valve under load and replace only the ones that failed.

Repairs are quoted once we know what failed. See boiler repair and radiant floor repair for typical repair pricing.

Cold floors in Corte Madera or Larkspur? Book a visit.

King tides, Corte Madera Creek and the mechanical room

In January 2026, storms and king tides swelled Corte Madera Creek into the Lucky Drive neighborhood and flooded Highway 101, and a failed pumping station added to the strain on Town crews, as ABC7 reported. The Town’s own shoreline planning lists high tides, stormwater that can’t drain when outfalls are underwater, ground settlement and sea level rise as the causes of bayside flooding. For a boiler, that comes down to a few practical questions.

  • How high is the boiler and its wiring? In a garage or ground-level mechanical room, a wall-hung boiler with pumps and controls mounted up off the slab keeps the electronics clear of a few inches of water.
  • Where does the condensate go? A condensing boiler drains water every time it runs. If that drain backs up when the ground is saturated, the boiler shuts itself down.
  • Has any part of it been underwater? If so, leave it off. NTI’s TRX installation manual says a boiler that has been submerged must be replaced, and that flood damage isn’t covered by the product warranty. A technician should inspect it before anyone tries to restart it.
  • Is there a pump for the water that gets in? See our ejector pump service for low rooms that take on water.

Fix the parts, or replace the boiler?

In both of the replacements above, the boiler was only part of the job. The expansion tanks, autofill, separators, filters and mixing valve around it decide whether a new boiler lasts.

Repair makes sense when…

  • Combustion readings are clean and the heat exchanger holds
  • The failure is one item, such as a circulator, a sensor, an expansion tank or a fill valve
  • The brand still has parts and support
  • The system holds pressure once a leak is fixed

Start planning a replacement when…

  • The heat exchanger is leaking or badly scaled
  • You have two aging boilers and one has already failed
  • Repair calls keep coming back every heating season
  • The mechanical room needs rebuilding anyway (tanks, separator, mixing, autofill)
  • Floodwater reached the controls

What goes into a mechanical-room rebuild

  • Air and dirt removal. An air separator and a magnetic dirt filter protect a new heat exchanger from sludge left in older loops.
  • Pressure control. A new autofill with backflow protection, a pressure-reducing valve and correctly charged expansion tanks.
  • Mixing for the floors. Radiant slabs want cooler water than an indirect tank, so a thermostatic mixing valve keeps each side at its own temperature.
  • Hot water sized to the house. A compact wall-mounted indirect like the S20W, or a large storage tank like the 116-gallon one in Corte Madera, depending on how many showers run at once.
  • Monitoring. Wi-Fi setup so the owner can see a fault before the floors go cold.

We install and service NTI, Navien, Lochinvar, HTP and Viessmann boilers. See boiler replacement and our NTI boilers page.

What boiler and radiant work costs in Corte Madera and Larkspur

These are the 2026 ranges we publish on our boiler pages. Where a job lands depends on venting, piping, controls and access.

$8,500–$15,000 High-efficiency boiler replacement
$11,000–$16,500 Combi boiler (heat + hot water)
$12,000–$18,000 Radiant heating boiler system
$19,000–$29,000 Boiler + indirect water heater
+$1,200–$4,500 Pump, manifold and valve upgrades
Custom quote Two-boiler rooms, full mechanical-room rebuilds, added zones

Common repairs from our boiler repair price list: radiant heat loop purge $450–$900, expansion tank replacement $380–$750, circulator pump replacement $1,050–$1,800.

Get a Free Estimate 2026 pricing. Every home is different. Written estimate before any work.

Want to know where your house lands? Read our boiler replacement cost guide.

Permits, sewer districts and the Air District rule

Which office, which district

  • Corte Madera is an incorporated town, so a boiler permit goes through the Town. Larkspur is an incorporated city, so its own building division handles it. The unincorporated part of Greenbrae goes to the County of Marin. We confirm the address and pull the right permit.
  • Sewer laterals: Corte Madera is in Sanitary District No. 2, which requires a lateral inspection at sale or when work over $50,000 is done within three years. Larkspur is in the Ross Valley Sanitary District, which asks for a compliance certificate at sale, on a remodel over $75,000 or when a bathroom is added. We don’t do lateral work but can refer you if a heating remodel triggers it.

Gas boilers and Rule 9-6

  • The Bay Area Air District amended Rule 9-6 on November 4, 2026. For home boilers, the zero-NOx requirement starts with units manufactured after January 1, 2033.
  • Typical gas tank water heaters have an earlier date: units manufactured after January 1, 2028. A boiler-fed indirect tank is a different setup from a gas tank.
  • Nothing in it forces anyone to pull out a boiler that still runs. It governs what may be sold and installed after those dates, so a gas replacement is still an option today.

Corte Madera & Larkspur boiler FAQ

Who services boilers and radiant floors in Corte Madera and Larkspur?

We do. Local Plumbing is a licensed C-16 and C-36 contractor (Lic #1091739) working from our San Rafael shop, and we’re open 24/7. We’ve replaced boilers in both towns since October 2025. Call or text (415) 234-0370.

My boiler pressure drops every few days. Is that a leak?

Usually, yes. Water is leaving the system somewhere, and an autofill may be quietly replacing it. We test the zones one by one to find the loop that loses pressure, then locate the leak.

Can you fix a radiant line without tearing up the whole floor?

Often. We open only the leaking section, repair it and restart the loop. If the repair joint has to stay under the floor, we’ll tell you up front that we can’t warranty a joint left there, so you can choose before we start.

I have two old boilers. Do I need to replace both?

Not always. If one has failed and the other is the same age, it’s worth pricing both ways: fixing the one that failed, or replacing both along with the tanks and valves around them, as the Larkspur owner chose in April 2026. We’ll write up both so you can compare.

How much is a new boiler in Corte Madera or Larkspur?

For a straight swap to a high-efficiency boiler, plan on $8,500–$15,000. A boiler that also drives an indirect tank lands at $19,000–$29,000, and a dedicated radiant system at $12,000–$18,000. Pump, manifold and valve work adds $1,200–$4,500, and rooms with more than one boiler get priced on site.

Our garage flooded during the king tides. Is the boiler safe to restart?

If water reached the boiler, don’t restart it. Manufacturers such as NTI say a submerged boiler has to be replaced, not dried out. Call us to inspect it, and we’ll tell you what got wet and what it will take.

Are gas boilers being phased out in Marin?

Not yet. Rule 9-6 requires zero-NOx only for gas boilers manufactured after January 1, 2033. Until then, new gas boilers can be installed, and a working one never has to be removed.

We serve Corte Madera, Larkspur, Greenbrae and the rest of Marin from San Rafael. More: plumber in Corte Madera · plumber in Larkspur · boilers & radiant heating · boiler replacement · boiler replacement cost · boiler repairs · contact us.

Pressure dropping, floors cold, or two boilers near the end?

Text us a photo of the boiler and its pressure gauge, or just describe the symptom, and we’ll book a time that works.